Connecting to AC Power

The device receives power from a standard alternating current (AC) electrical outlet. The connection is made through the supplied AC power cord.

AC Power Specifications

Physical Specification

Value

Input Voltage

Single universal AC power supply 100 to 240V

AC Input Frequency

50 to 60 Hz

AC Input Current

Mediant 800B: 4 A (max.)
Mediant 800C: 1.5 A (max.)

Max. Power Consumption

SBC Only (no PSTN):
Mediant 800B: 27W
Mediant 800C: 32W
Gateway: 60W (power consumption varies according to assembled hardware configuration)
The device must be connected to a socket-outlet providing a protective earthing connection.
To avoid electric shock or fire, use only the AC power cord that is supplied by AudioCodes with the device.
For replacing the power fuse, see Replacing the Power Fuse.

ご注意

本製品に添付の電源ケーブルは、Mediant 800 Gateway & E-SBC に専用設計されているため、汎用性がありません. 本電源ケーブルを他の機器に使用されないよう、ご注意ください.

To connect the device to AC power:
1. Connect the plug of the AC power cord (supplied) to the device's AC power socket (labeled 100-240V ~ 4A 50-60Hz), located on the rear panel.

Connecting to the Power Supply

2. Connect the plug at the other end of the AC power cord to a standard electrical outlet. The POWER LED, located on the front panel, lights up green.